Technical data
Separation: reduces in room |
>95% of 0,4µ particles or larger. Even mutagenic, carcinogenic and allergy producing substances which attach to particles. |
| |
|
Exhaust volume, max |
|
EHC HT35 |
35 m3/min |
EHC HT20 |
20 m3/min |
EHC HT10 |
10 m3/min |
| |
|
Temperature, max |
|
250°C |
|
| |
|
Filter life |
|
EHC HT35 |
~200 hours |
EHC HT20 |
~200 hours |
EHC HT10 |
~100 hours |
The lifetime is dependent on the engine size, engine type, how
it is used and engine condition. |
| |
|
Weight |
|
EHC HT35 complete |
40 kg |
EHC HT20 complete |
23 kg |
EHC HT10 complete |
18 kg |
EHC HT meets the TRGS 554 (D), COSHH (GB) regulation
and VERT Filter List (CH). The filter is disposable in normal
waste.
Formula to calculate the right model of
EHC HT
(Cylinder vol(litre)
x rpm
x efficiency*)/2000 =
Air consumption (N3/min)**
(Air consumption x
(exhaust temp + 273))/293 = Exhaust volume (m3/min)
*Efficiency
Aspirating engine = 0.85
Turboengine = 1.70
Turbo with intercooler = 1.85