Technical data
Reduces in room |
|
Particles |
> 99% of 0,12µ particles or larger |
CO |
~30% |
Nox |
~60% |
RC HO |
~90% |
HC |
~35% |
| |
|
Engine size |
Rpm, max |
EHC L20, |
max. 14 Litres 1200 r/min |
EHC L20 x 2 |
max. 30 Litres |
| |
|
Temperature |
|
Standard filterelement (4120171) |
200°C |
Reinforced filterelement (4120371) |
300°C |
| |
|
Filter life |
|
EHC L20 |
~100 starts |
The lifetime is dependent on the engine size, engine type, how
it is used and engine condition. |
| |
|
Weight |
|
EHC L20 complete |
5 kg |
EHC L20 x 2 complete |
11 kg |
EHC L20 meets the TRGS 554 (D), COSHH (GB) regulation,
and VERT Filter List (CH). The filter is disposable in normal
waste.
|